Fire Retardant Coating

product image

Fire Retardant Coating

FEUKEM FRC – 2 Hour Fire Rated Ductwork System

Phuket water-borne fire retardant coating formulated with special binder and fillers to provide excellent fire resistance to GI, MS duct, steel structure, and electrical cables for 120 minutes. It is globally advocated by consultants, contractors, and clients for ductwork in non-domestic kitchens, basements, enclosed car parks, smoke escape routes, stairways, and lobbies. It offers tremendous versatility in terms of design, application, robustness, rendering easy, time- saving and effective installation.

Special Features & Benefits:

    Fire Retardant conforms to BS 476 Part 6 & 7 - certified by CBRI Roorkee

    Tested for 2 hours (Flame directly exposed on duct sheet)

    Reduction in duct gauge construction or thickness

    Reduction in duct reinforcement

    Excellent Impact Resistance

    Anti Corrosive & Anti Bacterial

Application:

    Kitchen Exhaust Duct

    Car Park Extract Duct

    Smoke Extraction Duct

    Stair Pressurization Duct

Specification

All the Smoke Extract/Car Park Extract/Kitchen Exhaust/Stair Pressurization Ducts shall be required to provide a fire rating for a fully functioning ductwork system in case of a fire incident to provide sufficient time for proper evacuation to building occupants. These ducts shall be coated with Fire Retardant Coating of a minimum 700-micron (DFT) thickness to provide 2 hours Fire Rating. The Fire-Retardant Coating shall be tested as per requirements of BS 476: Part 6 ‘Class O’ and Part 7 ‘Class 1’. The Material shall be tested to confirm 2 hours fire rating with NIL flame spread when directly exposed to the Flame.

 Performance data:

Fire rating

Certified as per BS 476 Part 6 and 7 from CBRI Roorkee

2 hours fire performance

Certified with National Test House (NTH). Flame exposed directly on coating (700 micron DFT) at 1200 deg C

Impact Resistance

No Loss of adhesion – IS 5585 – 120 Nm

Corrosion Resistance

ASTM D 1654

Artificial Weathering

ASTM G 154

Pull off Strength

ASTM D 4541

Specific Gravity

1.38+/-0.02

Solid Content

65% +/-2%

Technical Coverage

1 – 1.2 kg/m2 with 0.7 mm DFT on Duct Surface

Application Temperature

- 5 to 55 Deg C

Shelf Life

12 months from the date of manufacturing

 

 

Call Us Now
+91 7982861686